What size generator do i need for hurricane season?

Check, uncheck or adjust the typical device list below — watts, startup surge and battery size update instantly. Numbers come from U.S. DOE, ENERGY STAR and manufacturer spec sheets, not marketing copy.

1. Check what you need to power

Refrigeration & Freezers

  • 1
  • 1

Kitchen

  • 1

Heating, Cooling & Fans

  • 1

Water & Pumps

Laundry & Cleaning

Electronics & Office

Medical Devices

Power Tools & Outdoor

Lighting

  • 4

2. Your sizing

Running load3,692 Wtypical range 1,363–1,414 W depending on your specific models
Startup peak5,852 Wdriven by 1× Sump Pump (1/2 HP, high-capacity)
Daily energy10,994 Wh
Recommended capacity13,750 Whincludes 25% margin for inverter loss & battery depth of discharge

3. Best cross-brand matches

No single portable power station covers this load — look at expandable systems (e.g., EcoFlow DELTA Pro 3 + extra battery, Anker SOLIX F3800 expansion packs) or a fixed home battery instead.

Static answer (crawlable summary)

Typical device list: Refrigerator (top-freezer, ~16 cu ft)×1, Freezer (chest, ~15 cu ft)×1, Window AC (12,000 BTU)×1, Dehumidifier (50-pint)×1, Sump Pump (1/2 HP, high-capacity)×1, Router + Modem×1, LED Bulb (60W equivalent)×4, Microwave Oven×1, Phone / Smartphone Charger×3.

Continuous load3,692 W
Startup peak5,852 W (driven by 1× Sump Pump (1/2 HP, high-capacity))
Daily energy use10,994 Wh
Recommended capacity13,750 Wh (25% margin included)
Minimum inverter4,070 W continuous

Frequently asked questions

What size generator do i need for hurricane season?

For a typical setup (refrigerator (top-freezer, ~16 cu ft), freezer (chest, ~15 cu ft), window ac (12,000 btu), dehumidifier (50-pint) and sump pump (1/2 hp, high-capacity)), you need at least 3,692W of continuous power. The single biggest moment is startup: when 1× sump pump (1/2 hp, high-capacity) kicks on, the momentary draw peaks at 5,852W. For overnight runtime we recommend at least 13,750Wh of battery capacity (your devices use about 10,994Wh per day, plus a 25% margin).

Which power stations can handle this?

Look for a station whose surge rating covers 5,852W and whose capacity is at least 13,750Wh.

Why is the startup surge higher than the running watts?

Motor-driven devices (fridge compressors, well pumps, air conditioners) draw 2-5× their running power for a split second at startup — measured as locked-rotor amps (LRA). A generator that only meets the running load will trip or stall when the biggest motor starts. Our data sources: U.S. DOE Energy Saver, ENERGY STAR certified product database, and manufacturer spec sheets (Franklin Electric, Goodman, Zoeller).

Related sizing guides