What size generator for home power outage?

Check, uncheck or adjust the typical device list below — watts, startup surge and battery size update instantly. Numbers come from U.S. DOE, ENERGY STAR and manufacturer spec sheets, not marketing copy.

1. Check what you need to power

Refrigeration & Freezers

  • 1

Kitchen

  • 1
  • 1

Heating, Cooling & Fans

  • 1
  • 1

Water & Pumps

Laundry & Cleaning

Electronics & Office

Medical Devices

Power Tools & Outdoor

Lighting

  • 4

2. Your sizing

Running load3,322 Wtypical range 114–134 W depending on your specific models
Startup peak4,822 Wdriven by 1× Furnace Fan (1/2 HP blower)
Daily energy9,130 Wh
Recommended capacity11,420 Whincludes 25% margin for inverter loss & battery depth of discharge

3. Best cross-brand matches

No single portable power station covers this load — look at expandable systems (e.g., EcoFlow DELTA Pro 3 + extra battery, Anker SOLIX F3800 expansion packs) or a fixed home battery instead.

Static answer (crawlable summary)

Typical device list: Refrigerator (top-freezer, ~16 cu ft)×1, Furnace Fan (1/2 HP blower)×1, Pellet Stove (PelPro PP130 class)×1, Electric Blanket (double)×1, Router + Modem×1, LED Bulb (60W equivalent)×4, Coffee Maker×1, Microwave Oven×1.

Continuous load3,322 W
Startup peak4,822 W (driven by 1× Furnace Fan (1/2 HP blower))
Daily energy use9,130 Wh
Recommended capacity11,420 Wh (25% margin included)
Minimum inverter3,660 W continuous

Frequently asked questions

What size generator for home power outage?

For a typical setup (refrigerator (top-freezer, ~16 cu ft), furnace fan (1/2 hp blower), pellet stove (pelpro pp130 class), electric blanket (double) and router + modem), you need at least 3,322W of continuous power. The single biggest moment is startup: when 1× furnace fan (1/2 hp blower) kicks on, the momentary draw peaks at 4,822W. For overnight runtime we recommend at least 11,420Wh of battery capacity (your devices use about 9,130Wh per day, plus a 25% margin).

Which power stations can handle this?

Look for a station whose surge rating covers 4,822W and whose capacity is at least 11,420Wh.

Why is the startup surge higher than the running watts?

Motor-driven devices (fridge compressors, well pumps, air conditioners) draw 2-5× their running power for a split second at startup — measured as locked-rotor amps (LRA). A generator that only meets the running load will trip or stall when the biggest motor starts. Our data sources: U.S. DOE Energy Saver, ENERGY STAR certified product database, and manufacturer spec sheets (Franklin Electric, Goodman, Zoeller).